<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>6039</ErrorNumber>
<ErrorFamily>Drum</ErrorFamily>
<ErrorMessage>
DRUM: Drum Position error during Velocity mode, (extra index possible cause, check monitor values)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
While the drum was spinning, or accelerating/decelerating to velocity, the position
error was much greater than allowable.  The threshold error is 2000 ticks plus an
extra factor based on the acceleration.
</text></DescriptionText>
<DescriptionText><text>
This error is most likely caused by a premature index that reset the counter.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume and report to Creo Response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
Premature index - check the encoder.
</Cause>
<Cause>
Faulty drum amp.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../error_messages/06036.xml</LinkAddress><LinkTitle>E_DRUM_VELOCITY_POS</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:27 2008 PST
</Updated>
<Links>
</Links>
</Error>